VG SS Series


Ürünler Description

Vega Chiller Ürünler
advanced divider
Vega Chillers

VG SS Series Air-Cooled Chiller (13–60 kW)

advanced divider

Single scroll; the existing table lists one compressor. Model duties: 13.5 / 26 / 42.5 / 61.5 kW. Plate evaporator.

Single scroll; the existing table lists one compressor. Model duties: 13.5 / 26 / 42.5 / 61.5 kW. Plate evaporator.

How to read the capacity range

The series label is a commercial range. Evaluate model-table values together with their rating conditions. For final selection, specify leaving-water temperature, ambient conditions and glycol concentration, then request model performance data at that duty.

Project inputs and calculation boundaries

For a quotation, specify approximate heat duty, fluid, inlet and outlet temperatures, flow, pressure loss and operating hours. Design ambient conditions, indoor or outdoor location and electrical infrastructure are also selection inputs. Flow and temperature readings must represent the same operating point. Do not transfer a catalogue capacity directly to different temperatures; confirm model performance at the required duty.

Commissioning and operating records

Check circuit cleanliness, filtration, air removal, proven flow and sensor readings. Record reference water temperatures and load conditions during commissioning. These values provide a baseline for maintenance and alarm investigations. Confirm pumps, tanks, connections and control options against the agreed quotation scope.

Frequently asked questions

Is the series capacity range sufficient for final selection?

No. Confirm the actual model at the required fluid temperature, ambient conditions, fluid properties and hydraulic duty.

Is cooling capacity the electrical consumption?

No. Cooling kW and electrical-input kW are different quantities. An energy assessment also needs actual load and operating hours.

What information is needed for a quotation?

Provide the industry or equipment, target temperature, approximate duty, flow, ambient conditions, operating hours and details of the existing system.

Data Section Description Units VG SS 13 VG SS 26 VG SS 45 VG SS 60
Technical Data Cooling Capacity kw 13,5 26 42,5 61,5
Cooling Capacity kcal/h 11.610 22.360 36.550 52.890
Compressor Refrigerant Circuits Quantity 1111
Number of compressors Quantity 1111
Evaporator Type – PLATE TYPE PLATE TYPE PLATE TYPE PLATE TYPE
Water Flow m³/h 2,3 4,4 7,3 10,5
Electrical Specifications Power Supply V-phz-Hz 400 / 3 / 50 400 / 3 / 50 400 / 3 / 50 400 / 3 / 50
Fan Fans Quantity 1 2 2 2
Hydraulic Water Tank LT 60 125 225 250
Water Pump HP 1 1,5 2,2 3
Water Connections inch 1” 1” 1 1/2” 2”
Dimension Length mm 1125 1500 1500 1750
Width mm 800 800 800 800
Height mm 1000 1150 1450 1600
Weight Transport Weight kg 250 325 360 460

Confirm rating temperatures, current model availability and options when requesting a quotation.

Mon – Sat | 9:00 AM – 6:00 PM

VEGA CHİLLERS

Your reliable partner for chiller sales and maintenance

Get your free site inspection and technical analysis today!