VG MS Series Air-Cooled Chiller (250–800 kW)

advanced divider

Multiple scroll; the model table lists 4 / 4 / 4 / 6 / 8 / 8 compressors. Shell-and-tube evaporator.

Multiple scroll; the model table lists 4 / 4 / 4 / 6 / 8 / 8 compressors. Shell-and-tube evaporator.

How to read the capacity range

The series label is a commercial range. Evaluate model-table values together with their rating conditions. For final selection, specify leaving-water temperature, ambient conditions and glycol concentration, then request model performance data at that duty.

Project inputs and calculation boundaries

For a quotation, specify approximate heat duty, fluid, inlet and outlet temperatures, flow, pressure loss and operating hours. Design ambient conditions, indoor or outdoor location and electrical infrastructure are also selection inputs. Flow and temperature readings must represent the same operating point. Do not transfer a catalogue capacity directly to different temperatures; confirm model performance at the required duty.

Commissioning and operating records

Check circuit cleanliness, filtration, air removal, proven flow and sensor readings. Record reference water temperatures and load conditions during commissioning. These values provide a baseline for maintenance and alarm investigations. Confirm pumps, tanks, connections and control options against the agreed quotation scope.

Frequently asked questions

Is the series capacity range sufficient for final selection?

No. Confirm the actual model at the required fluid temperature, ambient conditions, fluid properties and hydraulic duty.

Is cooling capacity the electrical consumption?

No. Cooling kW and electrical-input kW are different quantities. An energy assessment also needs actual load and operating hours.

What information is needed for a quotation?

Provide the industry or equipment, target temperature, approximate duty, flow, ambient conditions, operating hours and details of the existing system.

Data Section Description Units VG MS 250 VG MS 330 VG MS 400 VG MS 500 VG MS 660 VG MS 800
Technical Data Cooling Capacity kw 250 330 400 500 660 800
Cooling Capacity kcal/h 215.000 283.800 344.000 430.000 567.600 688.000
Compressor Refrigerant Circuits Quantity 222 344
Number of compressors Quantity 444 688
Evaporator Type – SHELL & TUBE SHELL & TUBE SHELL & TUBE SHELL & TUBE SHELL & TUBE SHELL & TUBE
Water Flow m³/h 43 56.7 68.8 86 113.5 137.6
Electrical Specifications Power Supply V-phz-Hz 400 / 3 / 50 400 / 3 / 50 400 / 3 / 50 400 / 3 / 50 400 / 3 / 50 400 / 3 / 50
Fan Fans Quantity 4 4 6 6 8 12
Hydraulic Water Tank LT OPT.OPT.OPT. OPT.OPT.OPT.
Water Pump HP OPT.OPT.OPT. OPT.OPT.OPT.
Water Connections inch DN100 DN125 DN125 DN125 2XDN125 2XDN125
Dimension Length mm 3000 3000 4000 4000 600 800
Width mm 235023502350 235023502350
Height mm 235023502350 235023502350
Weight Transport Weight kg 1170 1240 1400 1530 1700 2000

Confirm rating temperatures, current model availability and options when requesting a quotation.