VG DS Series Air-Cooled Chiller (50–200 kW)

advanced divider

Twin scroll; two compressors in the existing table. VG DS 55 has a plate evaporator; the other listed models have shell-and-tube evaporators.

Twin scroll; two compressors in the existing table. VG DS 55 has a plate evaporator; the other listed models have shell-and-tube evaporators.

How to read the capacity range

The series label is a commercial range. Evaluate model-table values together with their rating conditions. For final selection, specify leaving-water temperature, ambient conditions and glycol concentration, then request model performance data at that duty.

Project inputs and calculation boundaries

For a quotation, specify approximate heat duty, fluid, inlet and outlet temperatures, flow, pressure loss and operating hours. Design ambient conditions, indoor or outdoor location and electrical infrastructure are also selection inputs. Flow and temperature readings must represent the same operating point. Do not transfer a catalogue capacity directly to different temperatures; confirm model performance at the required duty.

Commissioning and operating records

Check circuit cleanliness, filtration, air removal, proven flow and sensor readings. Record reference water temperatures and load conditions during commissioning. These values provide a baseline for maintenance and alarm investigations. Confirm pumps, tanks, connections and control options against the agreed quotation scope.

Frequently asked questions

Is the series capacity range sufficient for final selection?

No. Confirm the actual model at the required fluid temperature, ambient conditions, fluid properties and hydraulic duty.

Is cooling capacity the electrical consumption?

No. Cooling kW and electrical-input kW are different quantities. An energy assessment also needs actual load and operating hours.

What information is needed for a quotation?

Provide the industry or equipment, target temperature, approximate duty, flow, ambient conditions, operating hours and details of the existing system.

Data Section Description Units VG DS 55 VG DS 75 VG DS 85 VG DS 125 VG DS 165 VG DS 200
Technical Data Cooling Capacity kw 55 76 85 117 155 200
Cooling Capacity kcal/h 47.300 65.360 73.100 100.620 133.300 172.000
Compressor Refrigerant Circuits Quantity 111 111
Number of compressors Quantity 222 222
Evaporator Type – PLATE TYPE SHELL & TUBE SHELL & TUBE SHELL & TUBE SHELL & TUBE SHELL & TUBE
Water Flow m³/h 9,4 13 14,6 20,1 26,6 34,4
Electrical Specifications Power Supply V-phz-Hz 400 / 3 / 50 400 / 3 / 50 400 / 3 / 50 400 / 3 / 50 400 / 3 / 50 400 / 3 / 50
Fan Fans Quantity 222 224
Hydraulic Water Tank LT 250300300 350350OPT.
Water Pump HP 343 5,55,5OPT.
Water Connections inch 2”2”2” 2 1/2”3”3”
Dimension Length mm 175026802680 282528253000
Width mm 80010001000 125012502350
Height mm 160013201320 200020002350
Weight Transport Weight kg 380 810 830 900 970 1000

Confirm rating temperatures, current model availability and options when requesting a quotation.